Indexing table - Rotary unit RDH-S

SKU
2661XX 0X00
Delivery Time
3 weeks
  • With precision transmission
    - High load capacity, rigid drive bearing
    - Absence of play and high tosional rigidity
  • Stepper or servomotor
  • Stainless design
  • No maintenance
Do you have any questions?
Your contacts for mechanical components:

Steffan Gärth
Steffan Gärth
Phone: +49 (0) 6659 / 981-773
Fax: +49 (0) 6659 / 981-776
steffan.gaerth@isel.com

Katja Henkel
Katja Henkel
Phone: +49 (0) 6672 / 86792-744
Fax: +49 (0) 6672 / 86792-777
katja.henkel@isel.com

RDH-S (Indexing table - Rotary unit)

Features
  • With precision transmission
    - High load capacity, rigid drive bearing
    - Absence of play and high torsional rigidity
  • Reduction 1:51 or 1:101
  • Stepper or servomotor
  • Protection class IP 65
  • Stainless design
  • Transfer accuracy <1.5 minute of arc
  • Repeatability < ± 6 seconds of arc
  • Available in solid or hollow shaft design
  • No maintenance

 

For pin assignment and transport loads see downloads datasheets!

Rotary axis RDH-XS RDH-S RDH-M
Catalogues and Flyer
Technical Data - Ordering Data Mechanics
pdf
(Size: 112.4 KB)
Transport loads, machining forces, feed
CAD data as download   

Simply register and log in, search and find the component you need and download the data.

Click here to download from the TraceParts server

The download is free of charge.

  Stepper motor MS 045 HT* EC servo motor EC 42 (brushless) DC servo motor RE 40 (brushed)       
< Reduction ratio 1:51 1:101 1:51 1:101 1:51 1:101
 Nominal output speed  [1/min]  4 2 22 11 22 11
at 1500 Hz (225 1/min) at 1100 1/min  
 Max. output speed  [1/min] 24 12 59 30
69
35
 
at 8000 Hz
---
 Nominal torque  [Nm]
7
11
4.8
9.2 4.6 9
at 1500 Hz 
---
 Max. torque (short term)  [Nm] 
--
--
7
11 7 11
 Rated holding torque (static load)  [Nm] 7 11 7 11 7 11
 Max. transmission load  [Nm] 18 28 18 28 18 28
  Limit for repeatable peak torque
 Dynamic load factor C  [N] 5800
 Static load factor CO  [N] 8600
 Weight  [kg] 4.6

* Values for half-step operation